AI-native diagnostics for UPS, Inverter & Battery

Backup power, read from design to daily operation.

Validate a UPS, inverter, and battery configuration before it's installed, monitor it continuously once it's running, or audit it once — no ongoing commitment required.

Built on IEC / IEEE / BEE standards Backup & power conditioning — Layer 4
INPUT breaker RECTIFIER / CHARGER BATTERY BANK INVERTER OUTPUT breaker STATIC BYPASS SWITCH RELIABILITY SAFETY EFFICIENCY
UPS INTERNAL SCHEMATIC — LAYER 4DCiERA
Three pillars, tracked separately

A UPS can be reliable and still unsafe. Safe and still wasteful.

The same three axes DCiEra tracks across the whole network, applied here to one unit — never collapsed into a single score.

R

Reliability

Fault history, standby readiness, and failure patterns tracked per physical unit — so you know which UPS in the fleet is actually degrading, not just which site had an incident.

S

Safety

Bypass-path integrity, breaker ratings checked against actual bus voltage, and earthing checked against IEC/IEEE/IS standards — flagged the moment a reading crosses a threshold.

E

Energy efficiency

Round-trip efficiency and backup-runtime loss translated into rupees — so a fading battery bank shows up as a number, not just a hunch.

Three ways to use this module

The same module, at whichever point in a UPS's life you need it.

1

Before it's installed

Design/pre-commissioning review validates a proposed UPS, inverter, or battery configuration against compatibility rules and calculated ratings before anything goes in. Used by dealers and OEMs quoting a job, consultants finalizing a design, and facility teams specifying their own expansion.

2

While it's running

Every incident is logged per physical unit, tagged by its role (main or standby), and continuously assessed on three independent axes — reliability, safety, and energy efficiency — never collapsed into one score. Used by maintenance teams on their own fleet, and by vendors staying engaged as the ongoing service relationship.

3

One-time engagement

A single audit's worth of data, uploaded once, feeds straight into that audit's findings — no ongoing monitoring commitment. Built for auditors running standalone engagements, including on behalf of clients not yet on DCiEra.

Who this is for

Five ways into the same module.

UPS dealers

Validate what you're about to sell, then keep serving it. Free unlimited technician seats for your field team.

Uses: Before + While

UPS OEMs

Size real, reactive, and apparent load before you design a solution — the same standards-backed check a consultant would use, from the manufacturer's side.

Uses: Before

Electrical consultants & contractors

You already hold the complete design — input/output wiring, full specs. That turns a generic compatibility check into a precise one.

Uses: Before

Electrical auditors

One engagement, one upload, one finding — no ongoing software relationship to manage afterward.

Uses: One-time

Facility maintenance teams

Whether you're specifying an expansion or keeping today's fleet healthy, it's the same platform either way.

Uses: Before + While
Not a generic checklist

Every finding is grounded in a real engineering knowledge base.

§

Governing formulas

Round-trip efficiency, backup runtime, and battery bus voltage under boost charge — sourced from BEE Books 3/4 and the relevant IEC/IEEE clauses, executed as real deterministic calculations, never left to AI memory.

△

Failure-mode signatures

How known UPS and battery faults actually present in logged data — the same content that powers symptom-triage hypothesis ranking when a technician reports a crude, free-text symptom.

✓

Standards backing

IEC 61000, IEEE 519, IS 3043 earthing checks, and BEE Book 3/4 benchmark curves by kVA band — cited specifically, not just referenced by name.